In factory production, when the workload of inoculation is very large, and it is necessary to work for a long time, the clean bench is an ideal equipment. The clean bench has the advantages of easy operation, more comfortable operation, high work efficiency, short preparation time, it can be operated for more than 10 minutes after booting, and can basically be used at any time.
The power supply of the clean workbench mostly adopts three-phase four-wire system, one of which is a neutral wire, which is connected to the casing of the machine, and should be firmly connected to the ground wire. The other three wires are all phase wires and the working voltage is 380V. There is a certain sequence in the three-wire connection circuit. If the thread is connected incorrectly, the wind will be reversed. At this time, the sound is normal or slightly abnormal. There is no wind on the front of the purification workbench. You can observe the movement with the flame of an alcohol lamp. Cut off the power supply, just swap the positions of any two-phase wires and connect them again. If the three-phase line is only connected to two phases, or if one of the three phases is in poor contact, the sound of the machine is very abnormal, and the power supply should be cut off immediately for careful inspection, otherwise the motor will be burned. These common sense should be clearly explained to the staff when starting to use the purification workbench, so as to avoid accidents and losses that should not be caused.


The air inlet of the purification workbench is on the back or under the front, and there is an ordinary foam plastic sheet or non-woven fabric in the metal mesh cover to block large particles of dust. It should be checked, removed and washed frequently. If the foam is found to be aging, it should be replaced in time. Except for the air inlet, if there are leaking holes, they should be sealed tightly, such as sticking tape, stuffing cotton, sticking glue paper, etc. There is a super filter in the metal mesh cover on the front of the workbench. The super filter can also be replaced. If it is used for a long time, the dust particles are clogged, the wind speed is reduced, and the aseptic operation cannot be guaranteed, it can be replaced with a new one.





The length of the service life of the purification workbench is related to the cleanliness of the air. In temperate areas, the purification workbench can be used in general laboratories. However, in tropical or subtropical areas, because the atmosphere contains high amounts of pollen or dusty areas, the purification workbench should be placed in a better room with double doors. use. Under no circumstances should the air inlet hood of the purification workbench face the open door or window, so as not to affect the service life of the filter.

The sterile room should be sprayed with 70% alcohol or 0.5% phenol to reduce dust and disinfect regularly. Use 2% Xinjieer to wipe the countertops and utensils. 70% alcohol is also possible. Use formalin? 40% formaldehyde plus a small amount of permanganic acid. Potassium is regularly sealed for fumigation, combined with ultraviolet sterilization lamps? Turn on for more than 15 minutes each time and other disinfection and sterilization methods, so that the sterile room can always maintain a high degree of sterility. The inside of the inoculation box should also be equipped with an ultraviolet light. Turn on the light for more than 15 minutes before using it for sterilization. However, there are still bacteria in the place where it is not exposed. When the UV lamp is turned on for a long time, it can stimulate the oxygen molecules in the air to associate to ozone molecules. This gas component has a strong sterilization effect and can sterilize the corners that are not directly illuminated by the ultraviolet rays. Since ozone is a health hazard, you should turn off the ultraviolet light before entering the operation, and you can enter it more than ten minutes after turning off.

The UV lamp can also be hoisted on the clean bench, but it should be installed outside the lampshade, and staggered and arranged in parallel, so as not to hinder the lighting during work. It is useless if the ultraviolet lamp is installed in the illuminating lampshade? glass plate, because ultraviolet rays cannot penetrate glass, and its lamp tube is made of quartz glass, not silicate glass.

The inoculation room strives to be concise, and all items that are not directly related to the work of the room cannot be put in to facilitate the maintenance of sterility. The air in the inoculation room should be absolutely isolated from the outside air, and the reserved air vents should be as tight as possible. The air vents can be equipped with upper and lower louvers. The area of the louvers should be slightly larger and need to be covered with 4 layers of gauze for simple dust filtering. After a day's work, the window can be opened to fully ventilate, and then sealed. In short, it must be clean, dust-free and sterile, and fresh air, suitable for work. The gauze covering the vent window should be changed and washed frequently. However, the above-mentioned measures are only ideal design schemes, which are often not easy to achieve comprehensively. In fact, as long as strict aseptic operation procedures, in the room with open doors and windows, and the protection of a clean bench, the pollution rate of inoculation can still be controlled and can be tolerated in production. Level.